The Philippine Agricultural Scientist
Publication Date
3-1-2024
Abstract
Instructions on building a do-it-yourself soil moisture sensor using Arduino microcontrollers abound on the Internet. These do-it-yourself soil moisture sensors are favorite projects by both plant and microcontroller enthusiasts because the parts are affordable and the end product is functional. In the absence of proper calibration, these soil moisture sensors cannot generate usable information on the status of plant-available-water in the soil. This research demonstrates the calibration of an Arduino-based soil moisture sensor using the soil moisture characteristic curve of a clay loam soil. Van Genuchten’s model was used to generate an equation and various parameters specific to the soil. An acceptable correlation was achieved between the soil volumetric moisture content and raw sensor value, with an R2 = 0.63. A highly significant result was achieved on the correlation between the actual and predicted soil moisture tension with a Mean Absolute Percentage Error (MAPE) of 7.5% and a p-value of less than the alpha value of 0.05. It is recommended that the technique demonstrated in this research be used by other researchers working on a similar setup.
Recommended Citation
Bato, Victorino A. and Alindogan, John Osbert
(2024)
"Method for Calibrating an Arduino-based Soil Moisture Sensor Using van Genuchten’s Equation,"
The Philippine Agricultural Scientist: Vol. 107:
No.
1, Article 5.
Available at:
https://www.ukdr.uplb.edu.ph/pas/vol107/iss1/5